From 2011 to 2014, the New York State Energy Research and Development Authority (NYSERDA) conducted 700 on-site inspections of single-family homes. This dataset contains detailed property and appliance-level data collected to verify self-reported survey information and enhance a statewide residential baseline study. The columns suggest it covers building characteristics, heating and cooling equipment, water heating, appliances, lighting, and observable operating behavior.
The future 'last updated' date on Socrata and Data.gov platforms is anomalous and should be treated with caution. The specific license governing use is not provided.
| # | Column Name |
|---|---|
| 1 | Other Large Appliances |
| 2 | Type/Style of Appliance |
| 3 | DHW Age |
| 4 | Number of DVD Players Plugged into Smart Strips or Outlets |
| 5 | Is HVAC Heating Energy Star? |
| 6 | Visual Condition of Cooling System |
| 7 | Solar DHW System Capacity (Gallons) |
| 8 |
| Pressurization or Depressurization |
| 9 | Does the new construction home contain an air duct system? |
| 10 | Fan Usage |
| 11 | Appliance Wattage |
| 12 | Year Building Built |
| 13 | Surface Type |
| 14 | Source for Solar DHW Capacity |
| 15 | Interior or cavity insulation quality (grade I-III) |
| 16 | Solar DHW System in Working Order? |
| 17 | Pool/Hot Tub Pump Speeds |
| 18 | Single Family or Multifamily |
| 19 | HVAC Heating Fuel Type |
| 20 | Number of Home Theater Systems Plugged into Smart Strips or Outlets |
| 21 | Construction Type |
| 22 | Number of Space Heaters Plugged into Smart Strips or Outlets |
| 23 | Window Glazing |
| 24 | Overall Window Condition |
| 25 | Gas Filled Window |
| 26 | Washing Machine Temperature |
| 27 | Number of VCR's Plugged into Smart Strips or Outlets |
| 28 | Is HVAC Cooling Primary or Secondary Source? |
| 29 | What Percentage of Conditioned Space Does the HVAC Cooling Unit Serve? |
| 30 | Status of Thermostat at Time of Inspection |
| 31 | Are HVAC Controlled Thermostats Programmable? |
| 32 | Set Point Temperature for Heating Season |
| 33 | Heating Setback Hours |
| 34 | Set Point Temperature for Cooling Season |
| 35 | HVAC Controls Thermostat Type |
| 36 | HVAC Systems Served |
| 37 | Storm Windows |
| 38 | Window Treatments |
| 39 | Bay Windows |
| 40 | When was HVAC Heating System Last Serviced? |
| 41 | Number of Lighting Controls |
| 42 | Number of Incandescent Light Bulbs |
| 43 | Location of Lighting Unit |
| 44 | HVAC Heating Manufacturer |
| 45 | HVAC Heating System Type |
| 46 | What Percentage of Conditioned Space Does the HVAC Heating Unit Serve? |
| 47 | HVAC Cooling Efficiency Data Source |
| 48 | Rated Efficiency of HVAC Cooling System |
| 49 | HVAC Cooling Capacity |
| 50 | HVAC Cooling Manufacturer |
| 51 | HVAC Cooling Manufacture Year |
| 52 | What Unit Does the HVAC Cooling System Serve? |
| 53 | Heating Setback Temperature |
| 54 | Cooling Setback Hours |
| 55 | Number of Doors |
| 56 | Interior or cavity insulation thickness (inches) |
| 57 | Interior or cavity insulation type |
| 58 | Exterior or continuous insulation type |
| 59 | Percent of total exterior and interior surfaces that are insulated |
| 60 | DHW Solar System presence |
| 61 | Storage Volume of the Unit (Gallons) |
| 62 | DHW Unit Heat Recovery |
| 63 | DHW Venting |
| 64 | Unit Energy Factor |
| 65 | DHW Model Number |
| 66 | DHW Unit Manufacturer |
| 67 | DHW Manufacture Year |
| 68 | Total air duct interior and exterior leakage |
| 69 | Air duct leakage to the outside |
| 70 | Television Screen Size (inches) |
| 71 | Refrigerator With Indoor Water Dispenser |
| 72 | Loads Per Week |
| 73 | Dishwasher Usage Pattern (cycles/week) |
| 74 | Dishwasher Efficiency Rating (Energy Factor) |
| 75 | Appliance Unit Manufacturer |
| 76 | Appliance Manufacture Year |
| 77 | Number of appliance units |
| 78 | Single and Multifamily Occupant (SMO) Telephone or Web Survey ID |
| 79 | Site ID |
| 80 | Measure ID |
| 81 | Equipment Category |
| 82 | Cooling Setback Temperature |
| 83 | No. of Water Heaters |
| 84 | DHW Type |
| 85 | Type of Other Light Bulbs |
| 86 | Number of Halogen Light Bulbs |
| 87 | HVAC Cooling Model Number |
| 88 | Construction Material of Building Envelope |
| 89 | Type of conditioned air being distributed by the duct system |
| 90 | Pool/Hot Tub Pump Horsepower |
| 91 | Heated Pool /Hot Tub |
| 92 | Pool/Hot Tub High Efficiency Pump |
| 93 | Size of Refrigerator or Freezer (cu ft) |
| 94 | Type of Building Served by DHW |
| 95 | DHW Age Known or Estimated |
| 96 | DHW Efficiency Data Source |
| 97 | Water Temperature Setting |
| 98 | Efficiency Rating of DHW Heat Recovery |
| 99 | Presence of orphan natural draft DHW |
| 100 | Thickness of DHW pipe insulation (inches) |
| 101 | DHW Insulation Thickness (inches) |
| 102 | Unit in Conditioned or Unconditioned Part of House |
| 103 | HVAC System Type |
| 104 | Type of Solar Technology used for DHW |
| 105 | Type of Solar DHW System |
| 106 | Ceiling Type |
| 107 | Depth Below Grade |
| 108 | Attic Access (sq. ft.) |
| 109 | Attic Access Insulation Level |
| 110 | Data source for the on-site inspector determining exterior or continuous insulation characteristics |
| 111 | Exterior or continuous insulation quality (grade I-III) |
| 112 | Exterior or continuous insulation thickness (inches) |
| 113 | Data source for the on-site inspector determining interior or cavity insulation characteristics |
| 114 | Does the home have perimeter insulation? |
| 115 | Window or Door |
| 116 | Door Material |
| 117 | Door Weather Stripping |
| 118 | Number of Windows |
| 119 | Window Size |
| 120 | U Factor |
| 121 | Window Frame Type |
| 122 | Number of Tier 2 Plug Loads, Smart Strips and Outlets |
| 123 | Number of Tier 1 Plug Loads, Smart Strips and Outlets |
| 124 | Number of Stereo Systems Plugged into Smart Strips or Outlets |
| 125 | Number of Printers and Copiers Plugged into Smart Strips or Outlets |
| 126 | Number of Gaming Consoles Plugged into Smart Strips or Outlets |
| 127 | Number of Fax Machines Plugged into Smart Strips or Outlets |
| 128 | Number of Cable Boxes Plugged into Smart Strips or Outlets |
| 129 | Description of Plug Loads |
| 130 | Number of Plug Loads |
| 131 | Number of T12 Light Bulbs |
| 132 | Number of Other Light Bulbs |
| 133 | Number of Efficient Light Bulbs |
| 134 | Type of Lighting Controls |
| 135 | Number of HVAC Ventilation Operating Hours Per Day |
| 136 | HVAC Ventilation System Configuration |
| 137 | HVAC Ventilation Space Served |
| 138 | HVAC Ventilation Type |
| 139 | Heating Ventilation Type |
| 140 | Does the HVAC Heating System have Thermostatic Radiator valves? |
| 141 | Does the HVAC Heating System Have an Outdoor Reset? |
| 142 | Electronically Commutated Motor Present |
| 143 | Location of HVAC Heating |
| 144 | Condition of HVAC Heating Furnace Air Filter |
| 145 | Is There An HVAC Heating Filter Slot Cover? |
| 146 | Visual Condition of Heating System |
| 147 | HVAC Heating Efficiency Data Source |
| 148 | HVAC Heating Efficiency Type |
| 149 | Rated Efficiency of Heating System |
| 150 | Number of HVAC Heating Systems |
| 151 | HVAC Heating Capacity |
| 152 | HVAC Heating Model Number |
| 153 | HVAC Heating Year Known or Estimated |
| 154 | HVAC Heating Year Manufactured |
| 155 | Is HVAC Heating Primary or Secondary Source? |
| 156 | When was HVAC Cooling System Last Serviced? |
| 157 | What Unit Does the HVAC Heating System Serve? |
| 158 | Condition of Furnace Air Filter |
| 159 | Location of Cooling System |
| 160 | HVAC Cooling Filter Slot Cover |
| 161 | HVAC Cooling Efficiency Type |
| 162 | Number of AC Units |
| 163 | HVAC Cooling Age Known/Estimated |
| 164 | HVAC Cooling System Type |
| 165 | Pool/Hot Tub Above Ground or In Ground |
| 166 | Is HVAC Cooling Energy Star? |
| 167 | DHW Fuel Type |
| 168 | Attic Access Weather Stripping |
| 169 | HVAC Fuel type |
| 170 | Climate Zone |
| 171 | Region |
| 172 | County |
| 173 | Appliance Category |
| 174 | Survey Weight |
| 175 | Location of Appliance Unit |
| 176 | Age of Unit Known or Estimated |
| 177 | Appliance Model Number |
| 178 | Appliance Fuel |
| 179 | Computer Monitor Type |
| 180 | Appliance Energy Star Certified? |
| 181 | Humidifier Usage |